demolition wood from EPZ (#1889)

ID-number#1889
Materialdemolition wood from EPZ
Classification ECN Phyllis classification ▸ treated wood ▸ demolition wood
NTA 8003 classification ▸ [100] hout ▸ [150] verwerkt hout
Submitter organisationECN (Netherlands)
Submission date2001-01-25
RemarksTo be used in gasification plant of EPZ, delivered to VTT for lab-tests, once crushed, VTT crushed it again, tested in CFB-gasifier at VTT
LiteratureE.Kurkela, et al: CFB gasification of biomass residues for co-combustion in large utility boilers - studies on ash control and gas cleaning. In: VTT Symposium 192: Power production from biomass III, pp. 213-227, Espoo (Finland) (1999).

Values

Property Unit Value Std dev Det lim Lab Date Method Remarks
ar dry daf

Fuel Properties

Proximate Analysis

Moisture content wt% 12.90
Ash content wt% 8.62 9.90
Volatile matter wt% 62.19 71.40 79.25
Fixed carbon wt% 16.29 18.70 20.75 Calculated

Ultimate Analysis

Carbon wt% 40.50 46.50 51.61 Measured
Hydrogen wt% 4.79 5.50 6.10 Measured
Nitrogen wt% 1.31 1.50 1.66 Measured
Oxygen wt% 31.88 36.60 40.62 Calculated
Total (with halides) wt% 100.00 100.00 100.00 Calculated

Calorific Values

HHVMilne MJ/kg 16.04 18.42 20.44 Calculated